Copyright © Siemens AG 2016. All rights reserved
381
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
Description:
Control signals of incorrect addressing at the multi-layer
AHB
Bit Identifier
Reset Attr. Function / Description
0 R_W
xh
r
h
Read/Write
0: read
1: write
3dt1 HSIZE
xh
r
h
HSIZE
6dt4 HBURST
xh
r
h
HBURST
Register:
QVZ_AHB_M
Address: 24h
Bits:
31dt0
Reset value: 0h
Attribu-
tes:
rh
Description:
Master detection for incorrect addressing at the multi-layer
AHB
Bit Identifier
Reset Attr. Function / Description
0 ARM_I
xh
r
h
ARM926-I
1 ARM_D
xh
r
h
ARM926-D
2 reserved
xh
r
h
reserved
3 PN
xh
r
h
PROFINET_IP
4 GDMA
xh
r
h
GDMA
5 HOSTIF
xh
r
h
Host Interface
6 reserved
xh
r
h
reserved
Register:
QVZ_APB_ADR
Address: 28h
Bits:
31dt0
Reset value: 0h
Attribu-
tes:
rh
Description:
Address of incorrect addressing at the APB
Bit Identifier
Reset Attr. Function / Description
31dt0 QVZ_APB_ADR
00000000 r Address of incorrect addressing at the