Copyright © Siemens AG 2016. All rights reserved
206
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
Register:
CR_Address_8
Address: 1Ch
Bits:
31dt0
Reset value:
FFCh
Attributes: (r) (w)
Description:
CR_Address
Bit
Identifier
Reset
Attr. Function / Description
1dt0 reserved
0h
11dt2 CR_StartAddress
3FFh
r w CR_StartAddress
15dt12 reserved
0h
25dt16 CR_EndAddress
0h
r w CR_EndAddress
26dt26 reserved
0h
27dt27 Zero_Data
0h
r w Read returns zero data
31dt28 New_Data_INT
0h
r w New_Data_INT
Register:
CR_Address_9
Address: 20h
Bits:
31dt0
Reset value:
FFCh
Attributes: (r) (w)
Description:
CR_Address
Bit
Identifier
Reset
Attr. Function / Description
1dt0 reserved
0h
11dt2 CR_StartAddress
3FFh
r w CR_StartAddress
15dt12 reserved
0h
25dt16 CR_EndAddress
0h
r w CR_EndAddress
26dt26 reserved
0h
27dt27 Zero_Data
0h
r w Read returns zero data
31dt28 New_Data_INT
0h
r w New_Data_INT
Register:
CR_Address_10
Address: 24h
Bits:
31dt0
Reset value:
FFCh
Attributes: (r) (w)
Description:
CR_Address
Bit
Identifier
Reset
Attr. Function / Description
1dt0 reserved
0h
11dt2 CR_StartAddress
3FFh
r w CR_StartAddress
15dt12 reserved
0h
25dt16 CR_EndAddress
0h
r w CR_EndAddress