“scanner sensor” - control of the parameters of the CMOS sensor installed in the scanner.
Inputs:
“pps”
SDT_INT
The required number of profiles per second (may be
limited by the scanner operation mode).
“expose1”
SDT_INT
Frame exposure time in s.
24.3.2.7. "Input and output" section
“Etnernet/IP” - transmitting and receiving data over Ethernet/IP. Only one instance of this
block is allowed on the graph.
Parameters:
“Input point”
1...256
Input assembly number (according to EIP
specification).
“Output point”
1...256
Output assembly number (according to EIP
specification).
“Assembly size”
1...512
Assembly size in bytes.
“Assembly map”
Input
Distribution of block inputs over the input assembly.
The values of the inputs will be located in
accordance with this parameter.
“Assembly map”
Output
Distribution of block outputs over the output
assembly. The values of the outputs must be
located in accordance with this parameter.
Inputs:
The inputs are created by the user using the context menu.