![background image](http://html.mh-extra.com/html/omron/v1000/v1000_user-manual_741325068.webp)
No.
Display
Name
Function
12
ALM LED Light
Refer to LED Screen Displays on page 67
.
13
REV LED Light
14
DRV LED Light
15
FOUT LED Light
u
Digital Text Display
Text appears on the LED Operator as shown below. This section explains the meaning of text as it appears on the display
screen.
Lit
Flashing
Table 4.2 Digital Text Display
Text
LED
Text
LED
Text
LED
Text
LED
0
9
I
R
1
A
J
S
2
B
K
T
3
C
L
U
4
D
M
<1>
V
5
E
N
W
<1>
6
F
O
X
none
7
G
P
Y
8
H
Q
Z
none
<1> Displayed in two digits.
u
LED Screen Displays
Display
Lit
Flashing
Off
When the drive detects an alarm or error
• When an alarm occurs
• oPE detected
• When a fault or error occurs during
Auto-Tuning
Normal state (no fault or alarm)
Motor is rotating in reverse
—
Motor is rotating forward
Drive Mode
Auto-Tuning
When FDBs are used
<1>
Programming Mode
Displays output frequency (Hz)
—
—
As illustrated in
this manual
STOP
<1> Refer to the FDBs instruction manual for further information.
u
LO/RE LED and RUN LED Indications
LED
Lit
Flashing
Flashing Quickly
<1>
Off
When run command is
selected from LED operator
(LOCAL)
—
—
Run command is selected from
device other than LED operator
(REMOTE)
During run
• During deceleration to stop
• When a run command is input
and frequency reference is 0
• During deceleration at a fast-
stop.
• During deceleration
• During stop by interlock
operation.
During stop
As shown
<1> Refer to
Figure 4.1
for the difference between “flashing” and “flashing quickly”.
4.2 Using the Digital LED Operator
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
67
4
Start-Up Programming & Operation
7/16/2008-13:23
Содержание V1000
Страница 11: ...Table of Contents This Page Intentionally Blank 10 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 27: ...1 4 Component Names This Page Intentionally Blank 26 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 37: ...2 2 Mechanical Installation This Page Intentionally Blank 36 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 63: ...3 12 Wiring Checklist This Page Intentionally Blank 62 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 221: ...5 11 U Monitor Parameters This Page Intentionally Blank 220 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 273: ...7 5 Drive Replacement This Page Intentionally Blank 272 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 287: ...8 6 Connecting an Option Card This Page Intentionally Blank 286 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 297: ...A 6 Drive Derating Data This Page Intentionally Blank 296 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 379: ...C 13 Self Diagnostics This Page Intentionally Blank 378 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 409: ...Index This Page Intentionally Blank 408 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 410: ...This Page Intentionally Blank SIEP C710606 20 OYMC AC Drive V1000 User Manual 409 ...