![Omron V1000 Скачать руководство пользователя страница 154](http://html.mh-extra.com/html/omron/v1000/v1000_user-manual_741325154.webp)
No.
Parameter Name
Setting Range
Default
E5-04
Number of Motor Poles
2 to 48
Depending on
E5-01
Note:
This parameter is not reset when the drive is initialized using A1-03.
n
E5-05: Motor Armature Resistance (PM OLV)
Set the resistance for each motor phase (not line-to-line resistance). When measuring the resistance manually make sure
to enter the resistance of one phase into E5-05.
No.
Parameter Name
Setting Range
Default
E5-05
Motor Armature Resistance
0.000 to 65.000 Ω
Depending on
E5-01
Note:
This parameter is not reset when the drive is initialized using A1-03.
n
E5-06: Motor d Axis Inductance (PM OLV)
Sets the d axis inductance in units of 0.01 mH.
No.
Parameter Name
Setting Range
Default
E5-06
Motor d Axis Inductance
0.00 to 300.00 mH
Depending on
E5-01
Note:
This parameter is not reset when the drive is initialized using A1-03.
n
E5-07: Motor q Axis Inductance (PM OLV)
Sets the q axis inductance in units of 0.01 mH.
No.
Parameter Name
Setting Range
Default
E5-07
Motor q Axis Inductance
0.00 to 600.00 mH
Depending on
E5-01
Note:
This parameter is not reset when the drive is initialized using A1-03.
n
E5-09: Motor Induction Voltage Constant 1 (PM OLV)
Set the induced phase peak voltage in units of 0.1 mV/(rad/s) [electrical angle]. Set this parameter when using an SSR1
series IPM motor with derated torque or an SST4 series motor with constant torque.
When E5-01 is set to “FFFF” use either E5-09 or E5-24 for setting the voltage constant.
No.
Parameter Name
Setting Range
Default
E5-09
Motor Induction Voltage Constant 1
0.0 to 2000.0 mV/(rad/s)
Depending on
E5-01
Note: 1.
Ensure that E5-24 = 0 when setting parameter E5-09. An alarm will be triggered, however, if both E5-09 and E5-24 are set 0, or if
neither parameter is set to 0.
2.
This parameter is not reset when the drive is initialized using A1-03.
n
E5-24: Motor Induction Voltage Parameter 2 (PM OLV)
Set the induced phase-to-phase rms voltage in units of 0.1 mV/(r/min) [mechanical angle]. Set this parameter when using
an SMRA Series SPM Motor.
When E5-01 is set to “FFFF” use either E5-09 or E5-24 for setting the voltage constant.
No.
Parameter Name
Setting Range
Default
E5-24
Motor Induction Voltage Parameter 2 (PM OLV)
0.0 to 2000.0 mV/(r/min)
Depending on
E5-01
Note: 1.
Ensure that E5-09 = 0 when setting parameter E5-24. An alarm will be triggered, however, if both E5-09 and E5-24 are set 0, or if
neither parameter is set to 0.
2.
This parameter is not reset when the drive is initialized using A1-03.
5.5 E: Motor Parameters
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
153
5
Parameter Details
7/16/2008-13:23
Содержание V1000
Страница 11: ...Table of Contents This Page Intentionally Blank 10 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 27: ...1 4 Component Names This Page Intentionally Blank 26 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 37: ...2 2 Mechanical Installation This Page Intentionally Blank 36 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 63: ...3 12 Wiring Checklist This Page Intentionally Blank 62 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 221: ...5 11 U Monitor Parameters This Page Intentionally Blank 220 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 273: ...7 5 Drive Replacement This Page Intentionally Blank 272 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 287: ...8 6 Connecting an Option Card This Page Intentionally Blank 286 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 297: ...A 6 Drive Derating Data This Page Intentionally Blank 296 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 379: ...C 13 Self Diagnostics This Page Intentionally Blank 378 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 409: ...Index This Page Intentionally Blank 408 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 410: ...This Page Intentionally Blank SIEP C710606 20 OYMC AC Drive V1000 User Manual 409 ...