![Omron V1000 Скачать руководство пользователя страница 357](http://html.mh-extra.com/html/omron/v1000/v1000_user-manual_741325357.webp)
n
RS-485 Interface
SI-485/J
OFF
S2
R+
R–
IG
S+
S–
SI-485/J
OFF
S2
R+
R–
IG
S+
S–
SI-485/J
ON
S2
R+
R–
IG
S+
S–
S+
S–
IG
R+
R–
PLC
Drive
Drive
Drive
Terminating
Register
Terminating
Register
Terminating
Register
Figure C.3 RS-485 Interface
Note:
• Turn on the DIP switch at the SI-485/J that is located at the end of the network. Turn it off at all other slaves.
• Set H5-07 to “1” when using the RS-485 interface.
n
RS-422 Interface
S+
S–
IG
R+
R–
PLC
SI-485/J
OFF
S2
R+
R–
IG
S+
S–
SI-485/J
OFF
S2
R+
R–
IG
S+
S–
SI-485/J
ON
S2
R+
R–
IG
S+
S–
Drive
Drive
Drive
Terminating
Register
Terminating
Register
Terminating
Register
Figure C.4 RS-422 Interface
Note:
• Turn on the DIP switch at the SI-485/J that is located at the end of the network. Turn it off at all other slaves.
• Set H5-07 to “0” when using the RS-485 interface.
u
Network Termination
The two ends of the MEMOBUS/Modbus network line have to be terminated. The drive has a built in terminating resistance
that can be enabled or disabled using DIP switch S2. If a drive is located at the end of a network line, enable the terminating
resistance by setting DIP switch S2 to the ON position. Disable the terminating resistance on all slaves that are not located
at the network line end.
Figure C.5
illustrates the setting of DIP switch S2.
C.4 Connecting to a Network
356
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
7/16/2008-13:23
Содержание V1000
Страница 11: ...Table of Contents This Page Intentionally Blank 10 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 27: ...1 4 Component Names This Page Intentionally Blank 26 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 37: ...2 2 Mechanical Installation This Page Intentionally Blank 36 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 63: ...3 12 Wiring Checklist This Page Intentionally Blank 62 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 221: ...5 11 U Monitor Parameters This Page Intentionally Blank 220 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 273: ...7 5 Drive Replacement This Page Intentionally Blank 272 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 287: ...8 6 Connecting an Option Card This Page Intentionally Blank 286 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 297: ...A 6 Drive Derating Data This Page Intentionally Blank 296 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 379: ...C 13 Self Diagnostics This Page Intentionally Blank 378 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 409: ...Index This Page Intentionally Blank 408 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 410: ...This Page Intentionally Blank SIEP C710606 20 OYMC AC Drive V1000 User Manual 409 ...