![Omron V1000 Скачать руководство пользователя страница 335](http://html.mh-extra.com/html/omron/v1000/v1000_user-manual_741325335.webp)
No.
Name
Description
Analog Output
Level
Unit
Control
Mode
Addr.
Hex
V/f O
LV
P
M
U1-19
MEMOBUS/Modbus Error
Code
Displays the contents of a MEMOBUS/Modbus error.
CRC Error
Data Length Error
Not Used
Parity Error
Overrun Error
Framing Error
Timed Out
Not Used
No output signal
available
–
A A A
66
U1-24
Input Pulse Monitor
Displays the Pulse Train input RP frequency.
32000
7D
U1-25
Software No. (Flash)
Flash ID
No signal output
avail.
4D
U1-26
Software No. (ROM)
ROM ID
No signal output
avail.
5B
U2: Fault Trace
Use U2 monitor parameters to view fault trace data.
U2-01
Current Fault
Display of the current fault.
No signal output
avail.
–
A A A
80
U2-02
Previous Fault
Display of the previous fault.
No signal output
avail.
–
A A A
81
U2-03
Frequency Reference at
Previous Fault
Displays the frequency reference at the previous fault.
No signal output
avail.
0.01
Hz
A A A
82
U2-04
Output Frequency at Previous
Fault
Displays the output frequency at the previous fault.
No signal output
avail.
0.01
Hz
A A A
83
U2-05
Output Current at Previous
Fault
Displays the output current at the previous fault.
No signal output
avail.
A A A
84
U2-06
Motor Speed at Previous
Fault
Displays the motor speed at the previous fault.
No signal output
avail.
0.01
Hz
− A −
85
U2-07
Output Voltage at Previous
Fault
Displays the output voltage at the previous fault.
No signal output
avail.
0.1 V A A A
86
U2-08
DC Bus Voltage at Previous
Fault
Displays the DC bus voltage at the previous fault.
No signal output
avail.
1 V
A A A
87
U2-09
Output Power at Previous
Fault
Displays the output power at the previous fault.
No signal output
avail.
0.1
kW
A A A
88
U2-10
Torque Reference at Previous
Fault
Displays the torque reference at the previous fault.
No signal output
avail.
0.1% − Α −
89
U2-11
Input Terminal Status at
Previous Fault
Displays the input terminal status at the previous fault.
Displayed as in U1-10.
No signal output
avail.
–
A A A
8A
U2-12
Output Terminal Status at
Previous Fault
Displays the output status at the previous fault. Displays the
same status displayed in U1-11.
No signal output
avail.
–
A A A
8B
U2-13
Drive Operation Status at
Previous Fault
Displays the operation status of the drive at the previous
fault. Displays the same status displayed in U1-12.
No signal output
avail.
–
A A A
8C
U2-14
Cumulative Operation Time
at Previous Fault
Displays the cumulative operation time at the previous
fault.
No signal output
avail.
1 H
A A A
8D
U2-15
Soft Starter Speed Reference
at Previous Fault
Displays the speed reference for the soft starter at the
previous fault.
No signal output
avail.
0.01
%
A A A
7E0
U2-16
Motor q-Axis Current at
Previous Fault
Displays the q-axis current for the motor at the previous
fault.
No signal output
avail.
0.10
%
− A A
7E1
U2-17
Motor d-Axis Current at
Previous Fault
Displays the d-axis current for the motor at the previous
fault.
No signal output
avail.
0.10
%
− A A
7E2
U3: Fault History
Use U3 parameters to display fault data.
U3-01
Most Recent Fault
Displays the most recent fault.
No signal output
avail.
–
A A A
90
(800)
U3-02
2nd Most Recent Fault
Displays the second most recent fault.
No signal output
avail.
–
A A A
91
(801)
U3-03
3rd Most Recent Fault
Displays the third most recent fault.
No signal output
avail.
–
A A A
92
(802)
U3-04
4th Most Recent Fault
Displays the fourth most recent fault.
No signal output
avail.
–
A A A
93
(803)
U3-05
5th Most Recent Fault
Displays the fifth most recent fault.
No signal output
avail.
–
A A A
804
U3-06
6th Most Recent Fault
Displays the sixth most recent fault.
No signal output
avail.
–
A A A
805
B.2 Parameter Table
334
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
7/16/2008-13:23
Содержание V1000
Страница 11: ...Table of Contents This Page Intentionally Blank 10 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 27: ...1 4 Component Names This Page Intentionally Blank 26 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 37: ...2 2 Mechanical Installation This Page Intentionally Blank 36 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 63: ...3 12 Wiring Checklist This Page Intentionally Blank 62 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 221: ...5 11 U Monitor Parameters This Page Intentionally Blank 220 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 273: ...7 5 Drive Replacement This Page Intentionally Blank 272 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 287: ...8 6 Connecting an Option Card This Page Intentionally Blank 286 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 297: ...A 6 Drive Derating Data This Page Intentionally Blank 296 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 379: ...C 13 Self Diagnostics This Page Intentionally Blank 378 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 409: ...Index This Page Intentionally Blank 408 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 410: ...This Page Intentionally Blank SIEP C710606 20 OYMC AC Drive V1000 User Manual 409 ...