No.
Name
Description
Range
Def.
Control
Mode
Addr.
Hex
Pg.
V/f O
LV
P
M
b6-01
Dwell Reference at Start
The Dwell function is used to temporarily hold the frequency
when driving a motor with a heavy load.
Parameters b6-01 and b6-02 set the frequency to hold and the
time to maintain that frequency at start.
Parameters b6-03 and b6-04 set the frequency to hold and the
time to maintain that frequency at stop.
b6-01
b6-02
b6-03
b6-04
OFF
Run command
Output
Frequency
Time
ON
0.0 to
400.0
0.0
Hz
A A A
1B6
123
b6-02
Dwell Time at Start
0.0 to 10.0 0.0 s A A A
1B7
123
b6-03
Dwell Frequency at Stop
0.0 to
400.0
0.0
Hz
A A A
1B8
123
b6-04
Dwell Time at Stop
0.0 to 10.0 0.0 s A A A
1B9
123
b8: Energy Saving
Use b8 parameters to configure the energy saving/conservation drive function.
b8-01 Energy Saving Control
Selection
Selects the Energy Savings function.
0: Disabled
1: Enabled
0,1
0
A A −
1CC
123
b8-02
<22>
Energy Saving Gain
Sets energy savings control gain when in Open Loop Vector
Control.
0.0 to 10.0 0.7
− A −
1CD
123
b8-03
<22>
Energy Saving Control Filter
Time Constant
Sets energy saving control filter time constant when in Open
Loop Vector Control.
0.00 to
10.00
0.50
<12>
− A −
1CE
123
b8-04
Energy Saving Coefficient
Value
Sets the Energy Saving coefficient and is used to fine
adjustments in V/f Control.
0.0 to
655.00
<57>
<51>
A − −
1CF
124
b8-05
Power Detection Filter Time
Sets a filter time for the Power Detection used by Energy
Savings in V/f Control.
0 to 2000 20 ms A − −
1D0
124
b8-06
Search Operation Voltage
Limit
Sets the limit for the voltage search operation performed by
Energy Savings in V/f Control. Set as a percentage of the
motor base voltage. Disabled when set to 0%.
0 to 100
0%
A − −
1D1
124
<1> Default setting value is dependent on parameter A1-02, Control Method Selection. The value shown is for A1-02 = 2-OLV control.
<2> Default setting value is dependent on parameter A1-02, Control Method Selection. The value shown is for A1-02 = 0-V/f Control.
<5> Default setting is dependent on parameter b5-20, PID Setpoint Scaling.
<12> Default setting value is dependent on parameter o2-04, Drive Model Selection.
<14> Default setting value is dependent on parameter o2-09, Initialization Spec. Selection.
<22> Parameter can be changed during run.
<32> A coasting motor may require a braking resistor circuit to bring the motor to a stop in the required time.
<33> Increase the setting value in increments of 0.1 when estimating the minimum output frequency for a motor coasting at high speed while
attempting Speed-Estimation Type Speed Search.
<34> Increase this value if an ov overvoltage fault occurs when performing Speed Search at start.
<51> Parameter value is changed if E2-11 is manuallychanged or changed by Auto-Tuning.
<57> Default setting value is dependent on parameter o2-04, Drive Model Selection and C6-01, Drive Duty Selection.
B.2 Parameter Table
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
303
B
Parameter List
7/16/2008-13:23
Содержание V1000
Страница 11: ...Table of Contents This Page Intentionally Blank 10 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 27: ...1 4 Component Names This Page Intentionally Blank 26 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 37: ...2 2 Mechanical Installation This Page Intentionally Blank 36 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 63: ...3 12 Wiring Checklist This Page Intentionally Blank 62 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 221: ...5 11 U Monitor Parameters This Page Intentionally Blank 220 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 273: ...7 5 Drive Replacement This Page Intentionally Blank 272 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 287: ...8 6 Connecting an Option Card This Page Intentionally Blank 286 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 297: ...A 6 Drive Derating Data This Page Intentionally Blank 296 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 379: ...C 13 Self Diagnostics This Page Intentionally Blank 378 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 409: ...Index This Page Intentionally Blank 408 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 410: ...This Page Intentionally Blank SIEP C710606 20 OYMC AC Drive V1000 User Manual 409 ...