A.6 Drive Derating Data
The drive can be operated at above rated temperature, altitude and default carrier frequency by derating the drive capacity.
u
Carrier Frequency Derating
As the carrier frequency of the drive is increased above the factory setting the drive capacity should be derated according
to
Figure A.1
.
ND
10 (8)
15
0
HD
2
Drive
Rating
Carrier (C6-02)
200 V Class:
80% of HD
400 V Class:
60% of HD
Carrier Frequency Derating
Figure A.1 Carrier Frequency Derating
u
Temperature Derating
As the ambient temperature for the drive is increased above the drive specification the drive should be derated. Additionally
parameter L8-35 Installation Method Selection on page
295
should be set according to enclosure type and mounting method
as illustrated in
Figure A.2
on page
295
.
n
Output Current Derating Due to Ambient Temperature
If the ambient temperature is above the drive specification or if drives are side-by-side mounted in a cabinet, the parameters
L8-12 and L8-35 must be set according to the installation conditions. The output current is derated as shown in
Figure
A.2
.
No.
Name
Description
Range
Def.
L8-12
Ambient
Temperature Setting
Adjust the drive overload (oL2) protection level when the drive is installed
in an environment that exceeds its ambient temperature rating.
40 to 60
40 °C
L8-35
Installation Method
Selection
0: IP20/Open-Chassis Drive
1: Side-by-Side Mounting
2: NEMA Type 1 Drive
3: Finless Drive or External Heatsink Installation
0 to 3
0
40
50
0
30
o
35
50%
70%
80%
85%
100%
o
o
o
Drive
Rating
Ambient tem
p C
Parameter L8-12
Parameter L8-35 = 0 (IP20/Open-Chassis Drive)
Parameter L8-35 = 2
(NEMA Type 1 Drive)
Parameter L8-35 = 1
(Side-by-side Mounting)
Parameter L8-35 = 3
(Finless Drive or External
Heatsink Installation)
Figure A.2 Ambient Temperature and Installation Method Derating
u
Altitude Derating
The drive standard ratings are valid for an installation altitude up to 1000 m. If the altitude exceeds 1000 m both the drive
input voltage and the rated output current must be derated for 1% per 100 m. The maximum altitude is 3000 m.
A.6 Drive Derating Data
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
295
A
Specifications
7/16/2008-13:23
Содержание V1000
Страница 11: ...Table of Contents This Page Intentionally Blank 10 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 27: ...1 4 Component Names This Page Intentionally Blank 26 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 37: ...2 2 Mechanical Installation This Page Intentionally Blank 36 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 63: ...3 12 Wiring Checklist This Page Intentionally Blank 62 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 221: ...5 11 U Monitor Parameters This Page Intentionally Blank 220 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 273: ...7 5 Drive Replacement This Page Intentionally Blank 272 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 287: ...8 6 Connecting an Option Card This Page Intentionally Blank 286 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 297: ...A 6 Drive Derating Data This Page Intentionally Blank 296 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 379: ...C 13 Self Diagnostics This Page Intentionally Blank 378 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 409: ...Index This Page Intentionally Blank 408 SIEP C710606 20 OYMC AC Drive V1000 User Manual ...
Страница 410: ...This Page Intentionally Blank SIEP C710606 20 OYMC AC Drive V1000 User Manual 409 ...