background image

BLE RS-232 adapter user manual V1.0

2018.05.22

Bluetooth V4.2 BLE 

RS-232 Serial Adapter

Model: BLE-232D-E

1. Package content:

BLE RS-232 adapter

White Box: 11 x 6 x 5 (cm)
Total Package Weight: 105 g

Package Contents:

BLE RS-232 adapter x 1

A4 User manual x 1

Mini USB Cable x 1

2. Profile:
2.1 Top view:

LED Status

Description

Data LED 

flash

Data transmission

Data LED solid on

No data transmission

Link LED solid on

BLE Link

Link LED flash

No Link

Data & Link LED solid on

DFU/OTA Mode

DB9 (Female)

Reset to Default

2 dBi Antenna

(5~27 VDC)

▼ GND

Mini USB (Power)

LED:
Link: Blue
PWR/Data: Red

1

Summary of Contents for BLE RS-232 Series

Page 1: ... 105 g Package Contents BLE RS 232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data LED solid on No data transmission Link LED solid on BLE Link Link LED flash No Link Data Link LED solid on DFU OTA Mode DB9 Female Reset to Default 2 dBi Antenna 5 27 VDC GND Mini USB Power LED Link Blue PWR Data Red 1 ...

Page 2: ...1 Enable 0 1 1 2 00 None 01 Odd 10 Odd 11 Even 0 Slave 1 Master 110 2400 111 4800 000 9600 001 19200 010 38400 011 57600 100 115200 101 23040 0 Remark 1 000000000 by default in red bold character 2 The GATT service and AT command will support more settings than the DIP switch please check the page 4 section 5 and page 5 section 6 2 3 DB9 connector Male DCE DTE DIP Switch 2 ...

Page 3: ... limit 3 2 There re 3 ways to power the adapter Mini USB 2P Terminal Block Blue and pin9 of DB9 please choose one Don t power the adapter by more than one source 3 3 The mini USB to type A cable is inside the standard package 4 Specifications 4 1 Default value Baud rate 9 600 bps Data bit 8 Parity none Stop bit 1 Flow control none Device Name BLE 232 Pin code 123456 if necessary 4 2 Serial Port Ba...

Page 4: ...T service and AT command will support all the functions please check the page 4 section 5 and page 5 section 6 4 3 Range max 50 m in open space The range is depend on the real environment 4 4 TX Power Max 3 dBm 4 5 RX Sensitivity 89 dBm typical 4 6 TX current consumption of 15 6 mA radio only 0 dbm 4 7 Operation Temperature 40 C to 70 C 4 8 Dimensions 87 mm L x 34 mm W x 18 mm H 4 9 Antenna Gain m...

Page 5: ...f 2 1 3 1 5 4 2 0x02 No Parity 0x01 Odd Parity 0x00 Even Parity Byte4 Byte5 Byte6 Baud Rate Device Mode Reset To Default 00 9600 01 19200 02 38400 03 57600 04 115200 05 230400 06 2400 07 4800 08 1200 09 460800 10 921600 0x01 on 0x00 off 0x01 Reset 6 Command set via COM port Command Value Description AT Check the connection status between control terminal and the RS 232 adapter Response OK when the...

Page 6: ...om the UART are not echoed back to the DTE DCE Default Y Command characters received from the UART are echoed back to the DTE DCE Inquire the current setting FLOW This command enable or disable flow control signals CTS RTS of the UART port Note the setting is not affected by DEFAULT The command will need 1 second delay Default N Disable flow control Y Enable flow control Inquire the current settin...

Page 7: ...e current role of the adaptor STATUS Inquire all the current setting of the adapter T Inquire the inner temperature of the IC in centigrade Display the current setting of the adapter STOP This command is used to specify one or two stop bits of COM port The command will need 200ms delay Default 1 One stop bit 2 Two stop bits Inquire the current setting VERSION This command is used to inquiry the fi...

Page 8: ...other one as the peripheral and link The central will link with the neighboring peripheral automatically The blue LED will be solid on The central will link with the paired peripheral on next time when power on Please reset to the default and follow the above procedures if you want to link with other BLE devices 8 APP The APP is used for the configuration and the data transmission test Scan and se...

Page 9: ...BLE RS 232 adapter user manual V1 0 2018 05 22 9 ...