— 7-38 —
B
B
3
3
t
t
y
y
p
p
e
e
B
B
5
5
t
t
y
y
p
p
e
e
7.1. General Operation and Function
7.1.19. Monitoring Analog Control
2
2
3
3
t
t
y
y
p
p
e
e
2
2
5
5
t
t
y
y
p
p
e
e
7.1.19. Monitoring Analog Control
l
The user may monitor the control states of Driver Unit shown in Table 7-13 below by the
voltage between the analog monitor pins (MON) and the analog ground (GND)
on the front
panel or the voltage between MON+ and MON- pins of connector C5 monitors.
l
The MN command selects a monitoring output.
Table 7-13
Item
RS-232C
Communication
Monitor
output
Description
Motor velocity
MN0
·
Monitors current velocity.
Velocity
command
MN1
·
Monitors velocity command given to the Motor.
Velocity error
MN2
·
Monitors errors between velocity command and
actual velocity. (per one sampling)
Torque
command
MN3
·
Monitors torque command.
øC exciting
current
MN4
·
Monitors exciting command given to ø C of the
Motor.
Moving distance
command
MN5
·
Monitors moving distance command given to the
Motor.
Data of position
error counter 1
MN6
·
Monitors residual pulses of the position error
counter. (in magnified scale)
Data of position
error counter 2
MN7
·
Monitors residual pulses of the position error
counter.
øC thermal
loading
MN8
Front panel
MON
(GND)
terminal
·
Monitors estimated temperature of ø C thermal
loading.
l
The monitor output scale is shown in Figure 7-36.
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...