10.1. Identifying Alarm
10.1.2. Using TA Command
2
2
3
3
t
t
y
y
p
p
e
e
2
2
5
5
t
t
y
y
p
p
e
e
10.1.2. Using TA Command
TA: Tell Alarm Status
Format :
TA ENT
l
The TA command reports an alarm status.
l
The same contents of alarm identification, which is indicated on the 7-segment LED on the front
panel, will be displayed on the screen.
l
However, the readout is not indicated in time-sharing like the LED.
*Example:
Excess position error and heat sink overheat alarms
:TA
F1>Excess Position Error
P0>Over Heat
:_
F1: Excessive position error alarm
P0: Heat sink overheat alarm
[Example 1] Identify an alarm as the warning lamp of ALARM is on.
(1) Confirm that the display of Handy Terminal shows the colon “: .”
(If the colon “:” is not shown in the display, press the ENTER key once.)
:_
(2) Input the TA command.
:TA_
A
T
(3) Press
the ENT key and the display identifies the alarm.
:TA
F1>Excess Position Error
:_
ENT
l
Thus the alarm is identified as “Excess position error.”
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...