— 8-36 —
B
B
3
3
t
t
y
y
p
p
e
e
B
B
5
5
t
t
y
y
p
p
e
e
8. Glossary of Command and Parameter
2
2
3
3
t
t
y
y
p
p
e
e
2
2
5
5
t
t
y
y
p
p
e
e
«
OR: Criterion, Overrun Alarm
Format
: OR data
Data range
: 204 800 to 819 200 [pulse]
Shipping set
: 409 600 [pulse]
Default
: Not available
l
This parameter sets the threshold of distance to report an overrun alarm.
l
The overrun alarm occurs when the error in the position error counter exceeds the sum of the
data of the CO and the OR parameters.
l
The TS or ?OR reports the current setting.
«
OS: Origin Setting Mode
Format
: OS data
Data
data
Position at where Home Return completes
1
Home Return completes when the Motor gets out the zone at where the
home position sensor is being ON.
3
Home Return completes when the Motor advances an offset distance
specified by the HO data after it got out the zone at where the home
position sensor is being ON.
4
Home Return completes when the Motor advances an offset distance
specified by the HO data after it gets in the zone at where the home
position sensor is being ON.
5
Home Return completes as soon as the Motor gets in the zone where
the home position sensor is ON.
6
Sets the current position as the home position.
Shipping set
: 4
Default
: Not available
l
This command sets the Home Return mode.
l
Refer to “6.2.1.2. Setting Home Position by Home Return” for more details.
l
The TS or ?OS command reports the current setting.
«
OTP: Over Travel Limit Switch Position
«
OTM: Over Travel Limit Switch Position
Format
: OTP data, OTM data
Data
: - 99 999 999 to + 99 999 999 [pulse], or /ST (teaching mode)
Shipping set
: 0 (OTP, OTM)
Default :
0
l
Sets the software over travel limit values in the position scale.
OTP : Sets the over travel limit value in the plus direction in unit of pulse.
OTM : Sets the over travel limit value in the minus direction in unit of pulse.
l
The OTP/ST and the OTM/ST commands enable to set limit switch positions with teaching.
(For more details, refer to “7.1.8.2. Software Over-travel Limit.”)
l
The TS or ?OT command reports the current setting.
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...