8. Glossary of Command and Parameter
NP: Notch Filter, Primary
Format
: NP data
Data
: 0 or 10 to 500 [Hz] or /AJ (Adjusting mode)
Shipping set
: 0
Default :
0
l
The NP parameter is used to specify the frequency of the primary notch filter of the velocity
loop.
l
If 0 is specified, the primary notch filter of the velocity loop is deactivated. In such a case,
“PRI.NF OFF” is displayed.
l
If a data other than 0 (i.e., 10 to 500) is entered, the data is adopted as the frequency.
l
The TS or ?NP command reports the current setting.
l
The NP/AJ command sets to adjusting mode.
NQ: Notch Filter, Q Parameter
Format
: NQ data
Data range
: 0.10 to 5.00
Shipping set
: 0.25
Default
: Not available
l
The NQ parameter is used to specify the Q parameter of the secondary notch filter of the velocity
loop.
l
The TS or ? NQ command reports the current setting.
NS: Notch Filter, Secondary
Format
: NS data
Data
: 0, 10 to 500 [HZ], or /AJ (adjust mode)
Shipping set
: 0
Default :
0
l
The NS data is used to set the frequency of secondary notch filter.
l
If 0 is specified, the 2nd stage notch filter will be set to OFF. In such a case the display shows
“SEC.NF.OFF.”
l
If the data other than “0” (i.e., 10 to 500) is specified, the frequency will be set to the data.
l
The TS or ?NS reports the current setting.
l
The NS/AJ starts adjusting program.
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...