2.1.2. Functional Setting of Driver Unit (Only for B3 and 23 Types)
l
Function of Input / Output ports for B3 and 23 type Driver Units requires the settings according
to the operation mode because they do not have extended I/O ports. (Setting options of Types 1
to 4, 7, and 8 are available. The shipping set is Type 1.)
l
The B5 and 25 type Driver Units do not require the settings.
l
The parameter TY selects the setting options of Input/Output ports.
Table 2-3
I/O type
Parameter
Operational function
Recommended operation mode
Type 1
TY1
Pulse train command. 16 program channels
Type 2
TY2
Pulse train command. 4 program channels. Jog.
·
Programmable Indexer
Type 3
TY3
Pulse train input. 4 program channels.
Hardware over travel limit
·
Programmable Indexer
·
RS-232C communication
Type 4
TY4
Pulse train command. 1 program channel
*1
.
Home Return start. Clear position error.
Hardware over travel limit.
·
Pulse train command
Type 7
TY7
Pulse train command. 1 program channel
*1
.
Jog. Hardware over travel limit
·
RS-232C communication
Type 8
TY8
Pulse train command. Eight program channels.
Position loop integrator frequency OFF*
2
.
·
Programmable Indexer
·
RS-232C communication
*1. Input for channel selection is not available. Start command RUN input uses the channel
0.
*2. When using the YSB Motor equipped with brake, the function of integration frequency
OFF (IOFF) will be a function for canceling brake clump by selecting the brake
sequence function. Moreover, ON/OFF of brake control and integral control can be done
automatically. Refer to “7.1.10. Brake” for more details of brake sequence.
!
Caution: Use function of “Position loop integrator frequency OFF” of Type 8 in the
following cases. When the Motor is locked by external force while the
integral control is being ON, the Motor heats up and the Driver Unit will
give “software thermal” alarm.
• If a holding brake is required while the Motor is stationary.
• If a locating pin or other mechanical locking device is required while the
Motor is stationary.
• If it requires applying a mechanical stopper while the Motor is stationary.
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...