8. Glossary of Command and Parameter
2
2
3
3
t
t
y
y
p
p
e
e
2
2
5
5
t
t
y
y
p
p
e
e
SG: Servo Gain
Format
: SG data
Data
: 0 to 30 [HZ], or /AJ (Adjust mode)
Shipping set
: 0
Default :
0
l
The SG parameter sets the maximum response frequency to the velocity loop.
à
Sets position loop gain SG in the automatic tuning.
l
When the SG value is changed, the parameters PG (position loop proportional gain), VG
(velocity loop proportional gain) and VI (velocity loop integration frequency) settings will be
automatically renewed.
l
The TS or ?SG reports the current setting.
l
The SG/AJ command starts the fine adjusting program.
l
If PG, VG, or VI is changed, the SG data will be cleared to 0.
«
SI: System Initialization
Format :
SI/data
Data range
: No data, /AL, /SY, /YS
Default
: No data
l
Resets all parameters
to the shipping set values. Please note that the SI command with optional
data AL, SY, and YS will delete all Programmable Indexers’ channel programs
l
The SI command can only be inputted immediately after entering the password, and when the
Motor is servo-off.
l
The following show the parameters that will be initialized with the SI command.
SI
: Initializes the servo-related parameters only. (PG, VG, VGL, VI, VIL, LG, TL, GP,
GT, FO, FP, FS, NP, NS, NQ, DBP, DBA, ILV, FF, FC, SG, and LO)
SI/AL : Initializes all parameters.
SI/SY : • For ESB23 and 25 type Driver Units, this command will initialize all parameters
excluding PA.
• For ESBB3 and B5 type Diver Units, this command will initialize all parameters
excluding PA and RO.
SI/YS : • For ESB23 and 25 type Driver Units, this command will initialize all parameters
excluding PA. The PA will be set to 700.
• For ESBB3 and B5 type Diver Units, this command will initialize all parameters
excluding PA and RO. Parameters PA and RO will be set to 700 and 2048,
respectively.
* Executing SI/AL entails resolver phase adjustment. Be careful not to interrupt the Motor
motion by an external force. (Do not perform above initializations only to the Driver Unit.)
!
Caution: It requires approximately 30 seconds to initialize the system. Do not turn
off the power while initializing. Otherwise, the memory error alarm occurs.
* When the error occurs, only the SI/AL command is valid even for the input of the SI or
the SI/SY.
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...