6.2. Position Control Mode Operation
6.2.2. Programmable Indexer Positioning Operation
6.2.2.1. Internal Program Channel Selection
l
The B5 and 25 type Driver Units specify a program channel to be executed by combinations of
ONs and OFFs of PRG0 to 5 inputs.
l
The B3 and 23 Driver Units specify a program channel to be executed by combinations of PRG0
to 3 input signals. Furthermore, the number of selectable channels depends on settings of the
input signals of parameter TY.
Table 6-5: Channel selection
B5 and 25 Driver Units
B3 and 23 Driver Units
PRGx ON/OFF combination
Channel
Selectable channel by I/O type
Channel
number
PRG5 PRG4 PRG3 PRG2 PRG1
PRG0
number TY1
TY2 TY3 TY4 TY7
TY8
0
OFF OFF OFF OFF OFF
OFF
0
ü
ü
ü
ü
ü
ü
1
OFF OFF OFF OFF OFF
ON
1
ü
ü
2
OFF OFF OFF OFF ON OFF
2
ü
ü
3
OFF OFF OFF OFF ON ON
3
ü
ü
4
OFF OFF OFF ON OFF
OFF
4
ü
ü
ü
ü
5
OFF OFF OFF ON OFF
ON
5
ü
ü
6
OFF OFF OFF ON ON OFF
6
ü
ü
7
OFF OFF OFF ON ON ON
7
ü
ü
8
OFF OFF ON OFF OFF
OFF
8
ü
ü
ü
9
OFF OFF ON OFF OFF
ON
9
ü
10
OFF OFF ON OFF ON OFF
10
ü
11
OFF OFF ON OFF ON ON
11
ü
12
OFF OFF ON ON OFF
OFF
12
ü
ü
ü
13
OFF OFF ON ON OFF
ON
13
ü
14
OFF OFF ON ON ON OFF
14
ü
15
OFF OFF ON ON ON ON
15
ü
16
OFF ON OFF OFF OFF
OFF
Available .
number of
channels
16 4 4 1 1
8
17
OFF ON OFF OFF OFF
ON
18
OFF ON OFF OFF ON OFF
19
OFF ON OFF OFF ON ON
20
OFF ON OFF ON OFF
OFF
21
OFF ON OFF ON OFF
ON
22
OFF ON OFF ON ON OFF
23
OFF ON OFF ON ON ON
24
OFF ON ON OFF OFF
OFF
25
OFF ON ON OFF OFF
ON
26
OFF ON ON OFF ON OFF
27
OFF ON ON OFF ON ON
28
OFF ON ON ON OFF
OFF
29
OFF ON ON ON OFF
ON
30
OFF ON ON ON ON OFF
31
OFF ON ON ON ON ON
32
ON OFF OFF OFF OFF
OFF
33
ON OFF OFF OFF OFF
ON
·
· · · · · ·
·
· · · · · ·
·
· · · · · ·
59
ON ON ON OFF ON ON
60
ON ON ON ON OFF
OFF
61
ON ON ON ON OFF
ON
62
ON ON ON ON ON OFF
63
ON ON ON ON ON ON
1) PRGx input ON/OFF combinations are the same as
those corresponding channel numbers of the B5 and
25 type Driver Units.
2) The maximum number of channels for B3 and 23
type Driver Units are limited to 16.
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...