9.3. Periodical Replacement of Parts
9.3.1. Motor
9.3. Periodical Replacement of Parts
9.3.1. Motor
l
There is no part that requires periodical replacement.
l
Refer to “9.2. Maintenance Check.”
9.3.2. Driver Unit
l
Electrolytic condenser
à
The gradual chemical change of electrolytic condensers will deteriorate the System
function and may result in the System failure.
Table 9-3
Parts
Function
Life
How to replace
Electrolytic condenser
Equalize power voltage
10 years
Replace *PCB.
Replace whole unit.
*PCB: Printed circuit board
l
Life of the electrolytic condenser relies on the operating conditions. The ten years of life is rough
estimation under continuous operation in normal room environment.
9.4. Storing
l
Store the Motors and the Driver Units in clean and dry indoor condition.
l
The Driver Units have a lot of ventilation openings. They should be covered properly to protect
from dust.
Table 9-4
Storing condition
Remarks
Temperature
- 20°C to + 70°C
–
Humidity
20 to 80%
No condensation
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...