7.2. For More Advanced Operation
7.2.6. Dead Band: DBP
7.2.6. Dead Band: DBP
Parameter: DBP (The password is necessary.)
l
The parameter DBP is used to specify a dead band for the deviation of position loop; the
deviation will be zeroed when it is under the set data of the parameter DBP.
l
This eliminates problems of small vibration after completion of positioning.
Table 7-23
Parameter Function
Shipping
set
DBP
Sets dead band to the position loop.
DBP0
l
The DBP parameter specifies a dead band on the position loop deviation in both sides of 0 (zero)
and zeroes the deviation when it is under the DBP setting.
l
In some use conditions, slight vibration may be caused due to minute deviation. Provision of a
dead band eliminates such slight vibration.
l
If a dead band is specified, repeatability of positioning accuracy will be deteriorated by the
amount of the dead band, though small vibration may be eliminated.
l
Unit of a dead band is the pulse. (Corresponds to the resolution of position sensor. Refer to
“2.7.2. Functional Specifications” for the resolution of position sensor.)
Figure 7-46
Velocity data
+
–
Position
command
Position loop
dead band
Position data
Velocity loop
integrator
Velocity
loop gain
Position
loop gain
+
–
VI
VG
PG
DBP
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...