10.2. Alarm List
10.1.3. Alarm History
10.1.3. Alarm History
l
The System stores the history of alarm occurrences to the EEPROM.
l
It keeps the record up to thirty-two alarm histories that have occurred. When the stored histories
reach to thirty-two, the oldest history will be deleted and the new history will be added to the
EEPROM.
l
This history records occurrences of alarms that make the DRDY output open or the OVER
output close.
l
Contents of the history record are as follows.
(i)
Alarm code that was shown on the LED.
(ii) Details of alarm for failure analysis of the manufacturer.
(iii) The number of times the power is turned on.
!
Caution: History of alarm may not be stored properly when the power is shut off
right after the alarm is reported.
u
Indication of Alarm History
(1) Input the TA command. Press the SP key to scroll the next line up.
:TA/HI
now time=8
0>F1-0, 4;
1>F1-0, 1;
2>F1-0, 1;
3>F1-0, 1;
4>A1-0, 1;
:_
H
A
/
···
SP
T
ENT
I
The current number of
times for turning on power.
The number of times for
turning on power when the
alarm is reported.
Details of alarm.
New
Alarm code.
Number of alarm.
u
Clear Alarm History
(1) Input the password.
:/NSK ON
NSK ON
:_
K
N
S
/
SP
N
ENT
O
(2) Input the TA command.
:/NSK ON
NSK ON
:TA/CL
:_
C
A
/
T
ENT
L
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...