— 4-3 —
B
B
3
3
t
t
y
y
p
p
e
e
B
B
5
5
t
t
y
y
p
p
e
e
2
2
3
3
t
t
y
y
p
p
e
e
2
2
5
5
t
t
y
y
p
p
e
e
4.2. Readout of Parameter
4.2.1. TS Command
4.2. Readout of Parameter
l
This section describes the procedures to read out current setting of parameters using the Handy
Terminal.
4.2.1. TS Command
l
Refer to “8. Glossary of Command and Parameter” for the details of TS command.
(1) Connect the Handy Terminal to the CN1 connector of the ESB Driver Unit, and then
turn on the power.
(2) Make sure that the colon (:) is displayed on the screen. (Press the ENT key once if
the colon is not on the screen.)
:_
ENT
(3) As an example, let’s read out the setting of parameter JV for Jog velocity.
The parameter JV belongs to a group of TS7 according to the description of TS
command shown in “8. Glossary of Command and Parameter.” Enter as shown below
to the Handy Terminal.
:TS7
MV1.00;
ENT
S 7
‘
T
The screen will show firstly the setting of the parameter MV for the velocity of the
Motor.
(4) Press
the SP key to scroll the display until it spots the setting of JV.
:TS7
MV1.00;
MA1.00,1.00;
JV0.10;
SP
•••
SP
(5) To quit the readout, keep pressing the SP key until the display stops scrolling or
enter the BS key. The colon will appear on the screen to indicate the completion of
readout.
MV1.00;
MA1.00,1.00;
JV0.10;
:_
BS
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...