Appendix 2: How to Check Motor Condition
Check resistance of the Motor winding
Appendix 2: How to Check Motor Condition
l
Examine resistance and insulation resistance of Motor winding to check if the Motor is in
normal condition. It can be regarded as normal if all check results are within the specification.
l
Firstly, check the winding resistance including the Motor cable. If the result is not satisfactory,
check the Motor only.
1 Check resistance of the Motor winding
Figure A-5: Checking with the cable
(Tester
)
(4)
(3)
(2)
(1)
Connector lock
Resolver cable
Motor cable
W
/
(7)
(6)
(5)
Figure A-6: Checking the Motor only
11 6 1
12 7 2
13 8 3
14 9 4
15 10 5
(Tester)
Connector lock
Ω/
Table A-9: Checking points
Cable connector
Motor connector
Result
Phase A
(1)
«
(2)
(A+) (A-)
(5)
«
(4)
(A+) (A-)
Phase B
(3)
«
(4)
(B+) (B-)
(10)
«
(9)
(B+) (B-)
Phase C
(5)
«
(6)
(C+) (C-)
(15)
«
(14)
(C+) (C-)
Table A-10: Resistance specification
Motor model
Winding resistance (
W)
Acceptable value
YSB2020
4.5
YSB3040
6.4
YSB4080
5.5
YSB5120
4.7
1. Within ± 30%
2. Variation between Phases A, B, and C: 1.0 maximum
l
For special Motor winding or long cable over 4m long, please consult with NSK.
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...