7.1. General Operation and Function
7.1.18. Monitoring via RS-232C Communication
2
2
3
3
t
t
y
y
p
p
e
e
2
2
5
5
t
t
y
y
p
p
e
e
Figure 7-24: Example of monitoring current position (TP2/RP)
:TP2/RP
123456
Monitoring current positioning
in unit of pulse
7.1.18.5. Monitoring Position Error Counter
l
The command TE reads out the data in the position error counter.
l
This is useful to check the settling state in positioning (state in approaching a target position).
à
Input format
TE/RP
/RP default : One shot readout
/RP attached : Real time readout
à
Press the BS key to terminate the real time readout (TE/RP).
Figure 7-25: Monitoring example (TE/RP)
:TE/RP
12
Monitored data of position
error counter in the unit of
pulse
7.1.18.6. Monitoring Motor Velocity
l
The TV command monitors velocity.
à
Input format
TV/RP
/RP default : One shot readout
/RP attached : Real time readout
à
Press the BS key to terminate the real time monitoring (TV/RP).
Figure 7-26: Monitoring example (TV/RP)
:TV/RP
1.2000
Indicates velocity in the unit
of s
-1
.
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...