10.3. Cause and Remedy of Alarm
2
2
3
3
t
t
y
y
p
p
e
e
2
2
5
5
t
t
y
y
p
p
e
e
u
Memory Error: E0
Cause Remedy
(1) Parameters stored in the memory have
been rewritten by noise or other cause.
·
Initialize the memory, and then reenter the
parameters.
·
(Refer to “8. Glossary of Command and
Parameter.”)
(2) Defective PCB.
(If the memory is not functioning after
initialized.)
·
Replace Driver Unit referring to “Appendix 4. How
to Replace ESB Driver Unit.)
à
The SI command (RS-232C communication) initializes the memory. After initializing,
some parameters will be reset to the shipping set. Resetting parameters to actual use
condition are necessary.
u
EEPROM Error: E2
Cause Remedy
(1) Defective EEPROM of control circuit.
·
Turn the power on again.
·
Replace Driver Unit referring to “Appendix 4. How
to Replace ESB Driver Unit.”
u
System Error: E7
Cause Remedy
(1) Defective ROM on PCB.
(2) Defective EEPROM on PCB.
·
Replace the Driver Unit referring to “Appendix 4.
How to Replace ESB Driver Unit.”
u
Interface Error: E8
Cause Remedy
(1) Defective I/O board in Driver Unit
·
Replace Driver Unit referring to “Appendix 4. How
to Replace ESB Driver Unit.”
u
Analog Command Error: E9
Cause Remedy
(1) Defective circuit of analog command input
·
Replace Driver Unit referring to “Appendix 4: How
to Replace ESB Driver Unit.”
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...