8. Glossary of Command and Parameter
TI:
Timer
Format
: TI data
Data range
: 0.3 to 100.0 [0.1 sec]
Default
: Not available
l
Sets a timer to an internal channel of the Programmable Indexer.
l
The TI parameter can only be set under the conditions where the CH command specifies a
channel to which the timer to be programmed, the Driver Unit outputs “?” indicating that the
System waits for a command to be entered.
l
The TC command reports the current setting.
«
TL: Torque Limit Rate
Fromat
: TL data
Data range
: 0 to 100 [%]
Shipping set
: 100
Default :
0
l
Sets the torque limit.
l
The Motor torque will be reduced to a percentage (%) specified by the TL command as soon as
it is inputted. The Motor torque will be controlled not to exceed the limit thereafter.
l
The TS or ?TL command reports the current setting.
«
TO: Software Travel Limit Over, Alarm Type
Format
: TO data
Data
: 1, and 2
Shipping set
: 2
Default
: Not available
l
Selects the format of alarm output of ‘Software over travel limit’ alarm.
Setting
DRDY output
OVER output
TO1
Open
Does not change.
TO2
Does not change.
Closed.
l
Regardless of the TO setting, the 7 segments LED and a readout with the TA command reports
the alarm status.
l
The TS or ?TO command reports the current setting.
Содержание MEGATORQUE M-ESB-YSB2020AB300
Страница 2: ...MEGATORQUE MOTOR SYSTEM User s Manual ESB Driver Unit System EC T Document Number C20140 01 ...
Страница 7: ... Blank Page ...
Страница 11: ... iv Blank Page ...
Страница 295: ... 8 66 B B3 3 t ty yp pe e B B5 5 t ty yp pe e 8 2 Parameter List 2 23 3 t ty yp pe e 2 25 5 t ty yp pe e Blank page ...
Страница 355: ...1st Edition 1st Printing November 20 2003 Document Number C20140 01 ...