node1_siteA::> metrocluster node show -fields configuration-state
dr-group-id cluster node configuration-state
----------- ---------------------- --------------
-------------------
1 node1_siteA node1mcc-001 configured
1 node1_siteA node1mcc-002 configured
1 node1_siteB node1mcc-003 configured
1 node1_siteB node1mcc-004 configured
4 entries were displayed.
11. Verify the operation of the MetroCluster configuration in Data ONTAP:
a. Check for any health alerts on both clusters:
system health alert show
b. Confirm that the MetroCluster is configured and in normal mode:
metrocluster show
c. Perform a MetroCluster check:
metrocluster check run
d. Display the results of the MetroCluster check:
metrocluster check show
e. Run Config Advisor. Go to the Config Advisor page on the NetApp Support Site at
support.netapp.com/NOW/download/tools/config_advisor/
After running Config Advisor, review the tool’s output and follow the recommendations in the
output to address any issues discovered.
12. Simulate a switchover operation:
a. From any node’s prompt, change to the advanced privilege level:
set -privilege advanced
You need to respond with
y
when prompted to continue into advanced mode and see the
advanced mode prompt (*>).
b. Perform the switchback operation with the -simulate parameter:
metrocluster switchover
-simulate
c. Return to the admin privilege level:
set -privilege admin
Step 6: Restore Storage and Volume Encryption functionality
After replacing the controller module or NVRAM module for a storage system that you
previously configured to use Storage or Volume Encryption, you must perform additional
steps to provide uninterrupted Encryption functionality. You can skip this task on storage
systems that do not have Storage or Volume Encryption enabled.
Step
1. Restore Storage or Volume Encryption functionality by using the appropriate procedure in
Encryption overview with the CLI
Use one of the following procedures, depending on whether you are using onboard or external key
725
Содержание AFF A700
Страница 4: ...AFF and FAS System Documentation 1...
Страница 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Страница 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Страница 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Страница 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Страница 437: ...1 Locate the DIMMs on your controller module 434...
Страница 601: ...Cabling SAS shelves in FAS9000 AFF A700 and ASA AFF A700 ONTAP 9 8 and later Cabling SAS storage ONTAP 9 8 and later 598...
Страница 605: ...602...
Страница 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Страница 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Страница 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Страница 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Страница 1462: ...Installing SuperRail to round hole four post rack 1459...
Страница 1602: ...1599...
Страница 1630: ...1627...
Страница 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Страница 1637: ...b Raise the drive handle to vertical c Use the handle to lift the drive from the drive drawer 1634...
Страница 1643: ...Callout Cable chain Connector Connects to Left Vertical Midplane Left Horizontal Drive drawer 1640...
Страница 1645: ...Guide rail 1642...
Страница 1648: ...Tab that you press to release the fan module handle 5 Use the fan module handle to pull the fan module out of the shelf 1645...
Страница 1669: ...Attention LED light on 1666...