9. If you are replacing another disk drive, repeat Steps 3 through 8.
10. Verify the disk drive’s activity (green) LED is illuminated.
When the disk drive’s activity LED is solid green, it means the disk drive has power. When the disk drive’s
activity LED is blinking, it means the disk drive has power and I/O is in progress. If the disk drive firmware
is automatically updating, the LED will be blinking.
11. If you disabled automatic drive assignment in Step 1, manually assign disk ownership, and then reenable
automatic drive assignment if needed:
a. Display all unowned disks:
storage disk show -container-type unassigned
b. Assign each disk:
storage disk assign -disk
disk_name
-owner
owner_name
You can use the wildcard character to assign more than one disk at once.
c. Reenable automatic drive assignment if needed:
storage disk option modify -node
node_name
-autoassign on
You need to reenable automatic drive assignment on both controllers in an HA pair.
12. Return the failed part to NetApp, as described in the RMA instructions shipped with the kit.
Contact technical support at
, 888-463-8277 (North America), 00-800-44-638277 (Europe),
or +800-800-80-800 (Asia/Pacific) if you need the RMA number or additional help with the replacement
procedure.
Hot-swap a disk drive in a DS460C disk shelf - shelves with IOM12 modules
You can hot-swap a failed disk drive in a DS460C disk shelf.
Before you begin
• The replacement disk drive must be supported by the DS460C disk shelf.
• All other components in the system must be functioning properly; if not, contact technical support.
• The disk drive you are removing must be failed.
You can verify the disk drive is failed by running the
storage disk show -broken
command. The
failed disk drive appears in the list of failed disk drives. If it does not, you should wait, and run the
command again.
Depending on the disk drive type and capacity, it can take up to several hours for the disk
drive to appear in the list of failed disk drives.
• If you are replacing a self-encrypting disk (SED), you must follow the instructions for Replacing an SED in
the ONTAP documentation for your version of ONTAP.
Instructions in the ONTAP documentation describe additional steps you must perform before and after
replacing an SED.
NetApp encryption overview with the CLI
1616
Содержание AFF A700
Страница 4: ...AFF and FAS System Documentation 1...
Страница 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Страница 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Страница 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Страница 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Страница 437: ...1 Locate the DIMMs on your controller module 434...
Страница 601: ...Cabling SAS shelves in FAS9000 AFF A700 and ASA AFF A700 ONTAP 9 8 and later Cabling SAS storage ONTAP 9 8 and later 598...
Страница 605: ...602...
Страница 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Страница 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Страница 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Страница 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Страница 1462: ...Installing SuperRail to round hole four post rack 1459...
Страница 1602: ...1599...
Страница 1630: ...1627...
Страница 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Страница 1637: ...b Raise the drive handle to vertical c Use the handle to lift the drive from the drive drawer 1634...
Страница 1643: ...Callout Cable chain Connector Connects to Left Vertical Midplane Left Horizontal Drive drawer 1640...
Страница 1645: ...Guide rail 1642...
Страница 1648: ...Tab that you press to release the fan module handle 5 Use the fan module handle to pull the fan module out of the shelf 1645...
Страница 1669: ...Attention LED light on 1666...