2.3 Troubleshooting Without Error Messages
VJ628XE-M-00
2.3.6 Other Problems
56
6
Ink spills around X rail
1. Tubes of Flushing box or Maintenance Assy may be
disengaged.
• Check if Tubes of Flushing box or
Maintenance Assy are disengaged.
• Replace Maintenance Assy.
• Replace Flushing box.
2. Is Waste fluid tube bent?
Make sure that approximately 160mm of Waste
fluid tube comes out downward from Leg holder
base (exploded view A-1).
-
3. Is Waste fluid tube clogged?
Replace Waste fluid tube.
-
4. Ink tube may be disconnected
Replace Ink tube.
5. CR board may be damaged.
Replace CR board.
6. Head may be damaged.
Replace Head.
7. MAIN board may be damaged.
Replace MAIN board.
Table 2-11 Symptoms, Check Items, And Actions(Continued)
No.
Symptom
Check item
Action
Reference