3.8.17 Replacing Carriage Assy
143
3.8 Replacing Cursor section
VJ628XE-M-00
18
Put the nozzle surface of the removed Print
head facing down and carefully place it on top
of the Poly-knit wiper in a stainless pan.
19
Remove CR encoder cable from th clamps on
the path.
A : Clamp
B : Cable
C :
20
Remove the screws (3 pieces) retaining CR
Board Base to Cursor.
A : Pan-head screw with spring washer and
flat washer M3
x
6
B : CR Board Base
21
Remove CR Board Base from Cursor.
CAUTION
CR Board Base is removed while Steel
Bare etc. are attached.
As load should not be applied to Steel
bare etc. , place it on a bubble wrap.
A
B
B
A
22
Remove Cutter Holder Assy.
3.8.9 Replacing Cutter Holder Assy
23
Loosen the adjusting screw (1 piece), and the
loosen tension of CR Belt.
A : Pan head small screwM4
x
35
B : CR Belt
24
Remove CR Belt from Cursor.
A : Cursor
B : CR Belt
B
A
B
A