2.2 Troubleshooting with Error Messages
VJ628XE-M-00
2.2.4 Error Messages during File Transmission
33
12
Internal error
Parameter save
error
Parameter writing failed. This should not normally happen.
FROM may be damaged.
Replace MAIN board.
13
Transfer failed
Wrong year xxxx
Received wrong year
data. (xxxx).
MAIN board may be damaged.
14
Transfer failed
Wrong month xx
Received wrong month
data. (xx).
15
Transfer failed
Wrong day xx
Received wrong date
data. (xx).
16
Transfer failed
Wrong hour xx
Received wrong time
data. (xx).
17
Transfer failed
Wrong min xx
Received wrong minute
data. (xx).
18
Transfer not ready
Transfer is not available. Check if the LED display on Operation panel is in
standby state in Board manager mode.
Press an arbitrary button on Operation panel to
set the panel display in the standby state, and
then reinstall.
Table 2-5 Error Messages During File Transmission(Continued)
No.
Message
Event/symptom
Check item
Action
Reference