3.10.8 Replacing Waste Fluid Tank
165
3.10 Replacing Maintenance
VJ628XE-M-00
3.10.8
Replacing Waste Fluid Tank
●
Tools & Jigs & Maintenance part
㨀㧵㧼
This section describes the procedure to replace the maintenance part, Waste Fluid
Tank Unit Assy.
In this section, it is referred to as Waste Fluid Tank.
Name
No.
Remarks
Waste Fluid Tank Unit Assy
DG-45368 Exploded View
Maintenance
Phillips screwdriver No.2
Generic
products
-
1
Removing R Side Cover.
2
Move Carriage to the opposite side of Platen.
3
Remove the screws (4 pieces) retaining
Waste Fluid Tank Holder.
A : Waste Fluid Tank Holder
B : Tapping screw M3
x
6 S Tight cup
A
B
A
B
4
Remove Waste Fluid Tank Holder.
NOTE
Since ink may drip, work covering with a
waste clothes etc. downward.
5
Replace Waste Fluid Tank.
6
To reassemble unit, reverse the removal
procedure.