3.11.3 Replacing Cartridge Holder
169
3.11 Replacing IH
VJ628XE-M-00
5
Remove the removed cables from the clamps
on the path.
6
Removing Heater Board Stay.
3.11.2 Removing Heater Board Stay
NOTE
This procedure is needed for replacing L-
side.
7
Loosen Joint Screw and then remove L Fitting
from Cartridge Holder.
A : Joint Screw
B : L Fitting
8
Remove the screws (2 pieces) retaining
Cartridge Holder to Cartridge Base.
A : Tapping screw M3
x
12S Tight cup
9
Remove Cartridge Holder.
A
B
A
10
Remove IH Cap and Twist Spring from
Cartridge Holder.
A : Cartridge Holder
B : IH Cap
C : Twist Spring
11
Replace Cartridge Holder.
12
Assemble the removed IH Cap and Twist
Spring to Cartridge Holder.
13
Assemble Cartridge Holder to Cartridge
Base.
A : Tapping screw M3
x
12S Tight cup
14
Attach the new O ring to the removed fitting,
and connect it to cartridge holder with the Joint
screw.
NOTE
• Replace O ring attached to Fitting with
New one.
• Attach O ring after dipping in dedicated
cleaning fluid.
15
To reassemble unit, reverse the removal
procedure.
A
B
C
A