3.8.6 Replacing P_EDGE Sensor
121
3.8 Replacing Cursor section
VJ628XE-M-00
3.8.6
Replacing P_EDGE Sensor
●
Tools & Jigs & Maintenance part
㨀㧵㧼
This section describes the procedure to replace the maintenance part,P-Edge
Sensor Assy.In this section n this section, it is reffered to as P_EDGE Sensor.
Name
No.
Remarks
P-Edge Sensor Assy
DG-43319 Exploded View Cursor
Phillips screwdriver No.2
Generic
products
-
1
Removing R Side Cover.
2
Remove Top Cover.
3
Remove Carriage Cover.
4
Remove CR Board Cover.
5
Remove P_EDGE Sensor from CR Board.
6
Remove P_EDGE Sensor from the clamps on
the path.
J11
7
Remove Cutter Holder Assy.
3.8.9 Replacing Cutter Holder Assy
8
Remove the screw retaining P_EDGE Sensor.
A : Pan-head screw with spring washer and
flat washer M3
x
6
B : P_EDGE Sensor
9
Replace P_EGDE Sensor.
10
To reassemble unit, reverse the removal
procedure.
11
Perform various adjustments.
A
B