3.7.6 Replacing PF Motor Cable
115
3.7 Replacing PF section
VJ628XE-M-00
3.7.6
Replacing PF Motor Cable
●
Tools & Jigs & Maintenance part
NOTE
This section describes the procedure to replace the maintenance part,PF Motor
Cable Assy.In this section n this section, it is reffered to as PF Motor Cable.
Name
No.
Remarks
PF Motor Cable Assy
DG-44699 Exploded View PF Motor
Phillips screwdriver No.2
Generic
products
-
Tension gauge
Max:40N(4,080gf
)
1
Remove R Side Cover and L Side Cover.
2
Remove Top Cover.
3
Remove PF Motor Cable from the connector
of PF Motor.
A : PF Motor Cable
B : connecting point
4
Remove the cable of PF Motor Cable from the
clamps on the path.
A
B
5
Remove PF Motor Cable from MAIN Board.
6
Replace PF Motor Cable.
7
To reassemble unit, reverse the removal
procedure.