3.6.14 Replacing P_REAR Sensor
109
3.6 Replacing Y Rail part
VJ628XE-M-00
3.6.14
Replacing P_REAR Sensor
●
Tools & Jigs & Maintenance part
㨀㧵㧼
• This section describes the procedure to replace the maintenance part,P_REAR
Sensor Assy.In this section, it is referred to as P_REAR Sensor.
• P_RAER sensor is located near the center of X rail.
Name
No.
Remarks
P_REAR Sensor Assy
DG-42945 Exploded View Y Rail Assy
Phillips screwdriver No.2
Generic
products
-
Phillips screwdriver No.1
for M2 screw
1
Remove Top Cover.
2
Remove P_REAR Sensor from MAIN Board.
3
Remove the cable of P_REAR Sensor from
the clamps on the path.
J26
4
Remove the screws (2 pieces) fixing Sensor
Plate.
A : Pan-head screw with spring washer and
flat washer M3
x
6
B : Sensor Plate
5
Remove the screws (2 pieces) retaining
Sensor Plate.
A : Cup screw M2
x
4
6
To reassemble unit, reverse the removal
procedure.
7
Perform various adjustments.
A
B
A