![MR ETOS IM Скачать руководство пользователя страница 237](http://html.mh-extra.com/html/mr/etos-im/etos-im_operating-instructions-manual_1844393237.webp)
7 Operation
Maschinenfabrik Reinhausen GmbH 2019
237
5163667/06 EN
ETOS
®
IM
Duration and date of next maintenance
You can use the parameter for the date of the next maintenance to define
the target date for the next maintenance. The duration parameter sets how
long this interval is to be. The device uses this to calculate the current main-
tenance progress.
Event (yellow)
You can use this parameter to set the maintenance progress (as a percent-
age) after which the device is to issue an event message (yellow).
To set the parameters for the operator interval, proceed as follows:
1. Go to
Settings > Parameters > Maintenance: OLTC operator
.
2. Select the parameter you want.
3. Set the parameter you want.
4. Press the
Accept
button to save the modified parameter.
7.20.2 Setting operator interval for transformer maintenance
You can define a maintenance interval of your choice for the transformer.
The maintenance interval is dependent on time. If the limit is reached (100
%), the device triggers an event message (red).
Figure 182: Operator interval for transformer maintenance
Activate interval
You can use this parameter to activate or deactivate the maintenance inter-
val.