![MR ETOS IM Скачать руководство пользователя страница 125](http://html.mh-extra.com/html/mr/etos-im/etos-im_operating-instructions-manual_1844393125.webp)
7 Operation
Maschinenfabrik Reinhausen GmbH 2019
125
5163667/06 EN
ETOS
®
IM
If you use this circuit, set the device as follows:
Parameter
Option
Voltage-transformer circuit
-
Current-transformer circuit
-
Phase angle correction
-30°
UI measuring channels
3-ph. voltage, 1-ph. current
Measurement mode
Phase-phase
Table 30: Circuit 3-C
Circuit 3-D
▪ Three-phase voltage measurement, single-phase current measurement.
▪ The voltage transformers are connected between the phases.
▪ The current transformer is connected to phase L2.
Parameter
Option
Voltage-transformer circuit
-
Current-transformer circuit
-
Phase angle correction
-150°
UI measuring channels
3-ph. voltage, 1-ph. current
Measurement mode
Phase-phase
Table 31: Circuit 3-D