136
2106
• Three or more MELSECNET/H and
MELSECNET/G modules in total are
mounted in the entire system.
• Three or more Ethernet interface
modules are mounted in the entire
system.
• Reduce the MELSECNET/H and
MELSECNET/G modules up to two or
less in the entire system.
• Reduce the Ethernet interface
modules up to two or less in the entire
system.
Q02U
• Five or more MELSECNET/H and
MELSECNET/G modules in total are
mounted in the entire system.
• Five or more Ethernet interface
modules are mounted in the entire
system.
• Reduce the MELSECNET/H and
MELSECNET/G modules up to four
or less in the entire system.
• Reduce the Ethernet interface
modules up to four or less in the
entire system.
QnU
*7
• Three or more MELSECNET/G
modules are mounted in the entire
system.
• Five or more MELSECNET/H and
MELSECNET/G modules in total are
mounted in the entire system.
• Reduce the MELSECNET/G modules
up to two or less in the entire system.
• Reduce the total number of the
MELSECNET/H and MELSECNET/G
modules up to four or less in the
entire system.
Qn(H)
*6
Error
Code
(SD0)
Error Contents and Cause
Corrective Action
Corresponding
CPU
*3
The function version is B or later.
*4
The function version is A.
*5
The module whose first 5 digits of serial No. is 04101 or later.
*6
The module whose first 5 digits of serial No. is 09012 or later.
*7
The Universal model QCPU except the Q02UCPU.