5
Example of EMC-compliant control panel
The following shows an example of the control panel concluded by Mitsubishi to be
compliant with EMC Directives. Produce a control panel by referring to the
example.
(a) Internal specifications of control panel
Increase the internal conductivity of the control panel as shown below,
in order to reduce the electromagnetic wave emitted by devices, and
protect the internal devices against the external electromagnetic wave.
Attach EMI gaskets and conducting adhesive tapes so that they will
come in contact with each other. This will increase the conductivity
of doors and control panel.
Galvanize the inner plate to increase the conductivity between the
internal device and control panel.
Wire
Contact
Inside
of door
Coming into contact with
the doors closed
EMI gasket or the back side
(the obverse side of the door)
*1: Do not apply coating to the parts where EMI gaskets and conducting adhesive tapes are to be attached.
*2: These wires are used to strengthen conductivity between the doors and control panel.
Screw
Shows an inner plate (galvanized at a thickness of 10 m or more) which is fixed
to the control panel with screws for conductivity.
Shows EMI gaskets (STG7-13 (Takeuchi Kogyo Co., Ltd.) or equivalent.
Shows conducting adhesive tapes (TR-9 (Takeuchi Kogyo Co., Ltd.) or equivalent.
Contact
Contact
Contact
Contact
Contact
Wire
Screw
Screw
Screw
Screw
Screw
Inside
of door
Inside of door
Inside of door
Inside
of door
Inside
of door