11.5 Prevent scatter (PREVENT SCATTER)
When full low turns on, the weighing material might disperse by the power when the
gate becomes full open at a dash according to a kind of weighing material or system.
Dispersion is prevented by gradually opening the gate. The control method is selectable
from [ARBITRARY CONTROL] or [QUADRATIC CONTROL].
[ARBITRARY CONTROL] can set up to 3 points of the open rate of the gate and the time
that reaches the open rate.
[QUADRATIC CONTROL] can set the time that reaches the open rate in full low. [OFF] is
set as default.
11.5.1
Switch to prevent scatter screen
The screen is switched from weighing screen to prevent scatter screen by the following
operation.
11.5.2
Arbitrary control of prevent scatter
Arbitrary control of scatter prevention can set up to 3 points of the open rate of the gate
and the time that reaches the open rate. The open rate is a relative value to the full low
position at the gate.
The setting range of open rate of the gate is from [0.000 %] to [100.000 %] and the
setting range of the completing time of full low is from [50 ms] to [10 000 ms].
Default setting:
When registering 3 points,
Point 1: Open rate of the gate [10.000 %], Time [500 ms]
Point 2: Open rate of the gate [25.000 %], Time [500 ms]
Point 3: Open rate of the gate [50.000 %], Time [500 ms]
O
pen
rat
e
[%]
Time [ms]
Open rate
of Full Flow
1. Select [MENU].
2. Select [BRAND CODE] in menu screen 1/2.
3. Select [PREVENT SCATTER] in brand code screen 1/2.
11 Weighing mode
Weight Controller CSD-918
Minebea Intec
EN-105