7
Under setpoint (UNDER)
The shortage value is set. The setting range is from [0] to [999 999], and input in
every [1] step with ten keys.
[0] is set as default.
When the weighing result is under the value of [ixed value-OVER], the output of
UNDER is turned on.
8 Near zero (Empty) (ZERO BAND)
The value that can output the signal of "Near zero" is set. The setting range is from
[0] to [999 999], and input in every [1] step with ten keys.
[0] is set as default.
The value of [?Gross weight?or?Net weight?] is under "Near Zero", and then Near
zero (ZERO BAND) output turns on.
Refer to Chapter
for the details.
9 Full (FULL)
The value that outputs the "Full" amount is set. The setting range is from [0] to [999
999], and input in every [1] step with the ten keys.
[0] is set as default.
When gross weight or net weight exceeds the "Full" value, the FULL output turns
ON.
Refer to Chapter
for the details.
10 AUTOMATIC FREE-FALL COMPENSATIOIN (A.F.F. COMPENSATION)
The efective width for the automatic free-fall compensation is set. The setting ran-
ge is from [0] to [999 999], and input in every [1]step with ten keys.
At the time of [0] setting, the automatic free-fall compensation turns of.
[0] is set as default.
Please refer to Chapter
for the details.
11 SUPPLEMENTARY FLOW TIME (SUPPLEMENTARY FLOW TIME)
The time of supplementary low is the function to apply ine low automatically du-
ring the ixed time when the status becomes a lack condition.
The setting range is from [0.00] to [99.99], and input in every [0.01] second with
ten keys.
[0.00] is set as default.
Please refer to Chapter
for the detailed timing chart.
12 JUDGE.AFTER S-FLOW WAIT (JUDGE. AFTER S-FLOW WAIT)
T
he judgment waiting time after supplementary low is set.
The setting range is from [0.00] to [99.99], and input in every [0.01] second with
ten keys.
[0.00] is set as default.
13 Accumulation value (ACCUM. VALUE)
This function is used in the conirmation or the clear of the accumulation value for
an efective brand.
When the accumulation value is cleared, the accumulation times of an efective
brand is also cleared.
11 Weighing mode
Weight Controller CSD-918
Minebea Intec
EN-97