7.4 Input efective state (INPUT ENABLED STATE)
The efective state of the input signal for alarm, OPEN side limit, CLOSE side limit, original
point sensor and ready can be selected.
The function becomes efective by shorting COM 3 and each signal when the input is
efective and [SHORT] is selected.
When COM 3 and each signal are opened and [OPEN] is selected, the function becomes
efective, refer to Chapter
for the details of servo controller interface signal.
7.4.1
Switch to screen of input efective state
Switch from weighing screen to the screen of input efective state by the following
operation.
7.4.2
Alarm signal (ALARM SIGNAL)
The input efective state of the alarm signal output from the servo ampliier is set.
[SV.ERR ALM] lights when the alarm signal becomes efective.
Alarm signal is selectable from [SHORT] or [OPEN].
[SHORT] is set as default.
7.4.3
Open side limit signal (OPEN LIMIT SENSOR)
When the limit sensor is used for opening / closing the gate, the input efective state of
OPEN side limit signal is set. When the OPEN side limit signal becomes efective, [SV.ERR
+LMT] lights and the gate stops.
The OPEN side limit signal is selectable from [SHORT], [OPEN] or [OFF].
[SHORT] is set as default.
Note:
The OPEN side limit signal and CLOSE side must use both by the pair. Either alone
cannot be used. Select both the OPEN side limit signal and the CLOSE side turning of
when not using this function.
7.4.4
Close side limit signal (CLOSE LIMIT SENSOR)
When the limit sensor is used for opening / closing the gate, the input efective state of
CLOSE side limit signal is set. When the OPEN side limit signal becomes efective, [SV.ERR
-LMT] lights and the gate stops.
The limit signal of side is selectable from [SHORT], [OPEN] or [OFF].
[SHORT] is selected as default.
1. Select [MENU].
2. Select [SERVO CALIBRATION] at menu screen 1/2.
3. Select [INPUT ENABLED STATE] in servo calibration screen.
1. Select [ALARM SIGNAL] in the screen of input efective state.
2. Select the input efective state of alarm signal.
3. Tap [OK].
1. Select [OPEN LIMIT SENSOR] in the screen of input efective state.
2. Select the input efective state of OPEN side limit signal.
3. Tap [OK].
Weight Controller CSD-918
7 Servo calibration
EN-60
Minebea Intec