7.3.3
Maximum frequency of input pulse (MAX. INPUT PULSE FREQ.)
Set the maximum frequency of input pulse [PPS] of servo ampliier used.
The setting range is 20 to 8 000 000 PPS.
1 000 000 PPS is set as default.
7.3.4
Command pulse method (COMMAND PULSE TYPE)
Set the command pulse method of servo ampliier used.
The pulse method is selectable from [1PULSE METHOD], [2PULSE METHOD] or [2PHASE
PULSE METHOD].
[2PULSE METHOD] is set as default.
7.3.5
Command pulse polarity (COMMAND PULSE POLARITY)
Set the system command pulse polarity of the gate in the OPEN direction.
The command pulse polarity can be selected from [CW] and [CCW].
[CCW] is the default.
OPEN
CCW
CW
Servo motor
7.3.6
Command pulse logic (COMMAND PULSE LOGIC)
Set the command pulse logic of servo ampliier.
The command pulse logic is selectable from [POSITIVE LOGIC] or [NEGATIVE LOGIC].
[POSITIVE LOGIC] is set as default.
2. Input the rating motor rotating speed [min
-1
] of servo motor with ten keys.
3. Tap [OK].
1. Select [MAX.INPUT PULSE FREQ.] at coniguration screen.
2. Input the maximum frequency [PPS] of input pulse by ten key.
3. Tap [OK].
1. Select [COMMAND PULSE TYPE] at coniguration screen.
2. Select the command pulse method.
3. Tap [OK].
1. Select [COMMAND PULSE POLARITY] on the coniguration screen.
2. Select the command pulse polarity.
3. Tap [OK].
1. Select [COMMAND PLUSE LOGIC] at coniguration screen.
2. Select the output logic of pulse.
3. Tap [OK].
7 Servo calibration
Weight Controller CSD-918
Minebea Intec
EN-55