6 Maximum time of post-batching (MAXTIME OF COMPENSATION)
The maximum time to apply the post-batching is set.
This input with ten keys in the range from 0 to 255 in every [1] step, and becomes
turning of when [0] is set.
[0] time is set as default.
7
Comparison low eval (COMPARISON FLOW EVAL)
The judgment condition at the time of executing post-batching is selectable from
[TIMER IS UP], [STAB. AND TIMER IS UP] or [STAB. OR TIMER IS UP].
When the [TIMER IS UP] is selected, the judgment is applied after the set time with
[WAITING TIME FOR JUDGE] has been passed.
When the [STAB. AND TIMER IS UP] is set, the judgment is applied when the set
time has passed with [WAITING TIME FOR JUDGE] and when the setting condition is
speciied (refer to Chapter
When the [STAB. OR TIMER IS UP] is set, the judgment is applied either when the
set time with [WAITING TIME FOR JUDGE] has been passed or when the setting con-
dition is speciied (refer to Chapter
[STAB. AND TIMER IS UP] is selected as default.
8 Automatic free fall compensation (A.F.F. COMPENSATION)
The operation of Automatic free fall compensation is selectable from [EFFECTIVE] or
[INVALID].
[INVALID] is selected as default.
9 Batch inish output of (BATCH FINISH OUTPUT OFF)
The condition of turning of the output of completing weighing is selectable from
[NO CONDITION], [LO OR UNSTABLE] or [ZERO BAND].
When the [NO CONDITION] is selected, FINISH signal is turned of either after the
set time with [BATCH FINISH OUTPUT IN] has been passed, or when the next start
signal is inputted.
When the [LO OR UNSTABLE] is selected, FINISH signal is turned of either when the
display becomes [OL] or [– OL], or when the output of Stable signal turns OFF.
When the [ZERO BAND] is selected, FINISH signal is turned of when Zero band sig-
nal is outputted.
[NO CONDITION] is set as default.
10 Tare batch start delay (TARE BATCH START DELAY)
The operation of tare is executed automatically after passing the waiting time for
batch start is selectable from [EFFECTIVE] or [INVALID].
[INVALID] is set as default.
11 Batch monitoring timer (BATCH MONITORING TIMER)
The timer that monitors the time from the input of Start signal to the output of Fi-
nish signal is set.
When the measuring time is longer than the set value, the error is output.
The error is [SQ. ERR 4] when [BATCH MODE] is selected in [CONTROL MODE].
This is input with ten keys within the range from 0 to 9 999 in every [1] second, and
this function becomes of when [0] is set.
[0] is set as default.
Weight Controller CSD-918
11 Weighing mode
EN-124
Minebea Intec