12 Batch start delay timer (BATCH START DELAY TIMER)
The waiting time from the input of Batch start signal to the start of Batch is set.
The time is input with ten keys in the range from 0 to 9 999 in every [1] second, and
this function becomes of when [0] is set.
[0] is set as default.
13 Fine low comparison stop timer (F-FLOW COMP. STOP TIMER)
The time to prohibit the comparison between the set value of Fine low and weig-
hed value at the time of start of Batching is set. This time is input with ten keys in
the range from 0.01 to 99.99 in every [0.01] second, and this function becomes of
when [0.00] is set.
[0.00] is set as default.
14 Middle low comparison stop timer (M-FLOW COMP. STOP TIMER)
The time to prohibit the comparison between the set value of Middle low and weig-
hed value at the time of inishing the Fine low is set. This time is input with ten keys
in the range from 0.01 to 99.99 in every [0.01] second, and this function becomes
of when [0.00] is set.
[0.00] is set as default.
15 Coarse low comparison stop timer (D-FLOW COMP. STOP TIMER)
The time to prohibit the comparison between the set value of Coarse low and mea-
sured value at the time of inishing the Middle low is set. This time is input with ten
keys in the range from 0.01 to 99.99 in every [0.01] second, and this function beco-
mes of when [0.00] is set.
[0.00] is set as default.
16 Waiting time for judge (WAITING TIME FOR JUDGE)
The waiting time until executing judgment after completing Fine low is set.
This time is input with ten keys in the range from 0.01 to 99.99 in every [0.01] se-
cond, and this function becomes of when [0.00] is set.
[0.00] is set as default.
17 Discharge monitor timer (DISCH. MONI. TIMER)
The timer that monitors the time from the Discharge start to Discharge inish is set.
When Discharge time is longer than the set value, the error is output.
This time is input with ten keys in the range from 0 to 9 999 in every [1] second, and
this function becomes of when [0.00] is set.
[0] is set as default.
18 Discharge gate close delay (DISCH.-GATE CLOSE DELAY)
The time from the condition that the measuring value is satisied with zero band to
closing the gate in executing the discharge is set.
This time is input with ten-keys in the range from 0.01 to 99.99 in every [0.01] se-
cond, and this function becomes of when [0.00] is set.
[0.00] is set as default.
19 Batch inish output on (BATCH FINISH OUTPUT ON)
The output time for Batch inish signal is set.
This time is input with ten-key in the range from 0.01 to 99.99 in every [0.01] se-
cond, and this function becomes of when [0.00] is set.
[0.00] is set as default.