11.3 Middle low (MEDIUM FLOW)
The control method of gate at middle low is set.
The control method is selectable from [FIXED OPEN (TIME)], [FIXED OPEN (WEIGHT)],
[ARBITRARY CONTROL] or [QUADRATIC CONTROL]. The open rate of the gate and the
completing time of middle low are set for [FIXED OPEN (TIME)] and the open rate of the
gate and the weight are set for [FIXED OPEN (WEIGHT)]
11.3.1
Switch to middle low screen
The screen is switched from weighing screen to middle low screen by the following
operation.
11.3.2
Middle low ixed open rate (time)
The open rate of the gate in middle low and the completing time of middle low are set.
The open rate is a relative value to the full open position at the gate. The setting range of
open rate of the gate is form [0.000 %] to [100.000 %] and the setting range of the
completing time of middle low is from [50 ms] to [10 000 ms].
[50.000 %] for open rate of the gate, and [50 ms] for the completing time of middle low
is set as default.
O
pen
rat
e
[%]
Time [ms]
Middle Flow
Full Flow
Note:
-
The open rate is a relative value to the full low position at the gate.
-
In this control method, the gate reaches the open rate set before at once, and is
maintained until the completing time.
1. Select [FULL FLOW] in coarse low screen, and select [FIXED OPEN (WEIGHT)]. And
then, tap [OK].
2. Tap [FIXED OPEN (WEIGHT)] in coarse low screen to inputting the each value.
3. Select [WEIGHT], and input the weight that reaches in coarse low with ten keys, and
then tap [OK].
4. Select [OPEN], and input the open rate of the gate with ten keys, and then tap [OK].
1. Select [MENU].
2. Select [BRAND CODE] in menu screen 1/2.
3. Select [MEDIUM FLOW] in brand code screen 1/2.