9.16 Accumulation
This function adds and accumulates the weighing data.
The brand accumulation function works when the accumulation command signal is input
or the automatic accumulation function is applied.
9.16.1
Accumulation command (ACCUM. COMMAND)
The operational condition when the accumulation command is input from the external I/O
is selectable from [IN STABLE MODE] or [ANYTIME].
[IN STABLE MODE] is selected as default.
When [ANYTIME] is selected, the accumuration command is always accepted.
When [IN STABLE MODE] is selected, the accumuration command is accepted only when
[STABLE] sign of the status display-1 lights.
9.16.2
Automatic accumulation function
Set the followings for applying the automatic accumulation:
-
The automatic accumulation function is switched to [SYNC. WITH FINISH] or [AUTO
ACCUM. AT STABLE] in weighing operation setting screen.
When [SYNC. WITH FINISH] is set, this funciton accumulates to synchronize with the
inish signal of the weighing.
When [AUTO ACCUM. AT STABLE] is set; this function accumulates to synchronize
with stable signal of the weighing.
-
Automatic accumulation condition is selectable from [IN OK MODE] or [NO
CONDITION] in weighing operation setting screen of the above same screen.
When [IN OK MODE] is set, the weighing data is accumulated if the [OK] sign in the
status display-1 lights when the signal set in "Automatic accumulation function" is
output.
This accumulation does not proceed if [OK] sign does not light.
When [NO CONDITION] is set, the weighing data is accumulated unconditionally
when the signal set in "Automatic accumulation function" is output.
9.16.3
Accumulation clear
Clear the accumulated value and the accumulation times of each brand on brand code
screen of by external control I/O (refer to Chapter
The range of Accumulation value is from –99 999 999 to 99 999 999.
The range of the accumulation times is from 0 to 999 999.
When the accumulation exceeds these ranges, the indicated amount of the accumulation
value and the accumulation times become red.
In such case, clear the accumulation value or accumulation times.
9.17 Graph trigger mode (GRAPHIC TRIGGER SETTING)
The trigger mode to draw in the graph is set.
[SINGLE]
By tapping [START], the weighing starts and graph draws on-
ce until the time of [T].
9 Basic function setting display (BASIC FUNCTION)
Weight Controller CSD-918
Minebea Intec
EN-83
Содержание CSD-918 Series
Страница 239: ......