Name
Contents
[CANCEL THE ACCUM.]
The previous one accumulation data is cancelled.
[M.F.F. COMPENSATION] The fall compensation is executed.
[ERROR RESET]
The error display is reset.
The targeted errors are [ZERO ERROR] (refer to Chap-
ter
) und [SEQUENCE ERROR] (refer to Chapter
).
[CLR ACM. OF BRAND]
The accumulation value and accumulation times of the brand
reading out at present is cleared.
[CLR ACM. OF ALL
BRAND]
The accumulation value and accumulation times of all brands
is cleared.
[HOLD]
The hold signal is input (Switch of ON and OFF).
10.3 Setting of external control I/O
Set the external I/O control.
The I/O connecter is mounted at rear panel of the unit.
Each of below function list can be optionally set.
10.3.1
Setting method of the external control I/O
10.3.2
Tables of external control input function
The function that can be set to the external control input is as follows.
Item
Contents
[OFF]
No setting
[GROSS / NET]
The display of Gross and Net is switched.
[ZERO]
Zero set is executed.
[ZERO CLEAR]
When zero set or the zero tracking is executed, the display is
returned to the state before the zero set and zero tracking.
[TARE]
The tare weight cancellation is executed.
[TARE CLEAR]
When tare weight cancellation is executed, the display is re-
turned to the state before the tare weight cancellation.
[BATCH START]
The signal to start batch is input.
[DISCHARGE START]
The signal to start discharge is input.
[MIXING START]
The signal to start mixing is input.
1. When the external control input is set, please select the function from I/O input 1 to 11
of I/O setting screen 2/6 and 3/6.
2. When the external control output is set, please select the function from I/O input 1 to
11 of I/O setting screen 4/6 and 5/6.
3. And when the external control output logic is set, please select the function from I/O
output logic in I/O setting screen 5/6.
4. Select the function to set, and tap [OK].
10 I/O setting (I/O)
Weight Controller CSD-918
Minebea Intec
EN-87