Check the analog output
↓
Is wiring correct?
→ No →
↓
Yes
↓
Connect wires surely (refer to
Chapter
Voltage output load resistance is
5 k
Ω
or more. Current output load
resistance is 510
Ω
or less.
→ No →
Apply the load resistance suitable
for the speciications.
↓
Yes
↓
Conirm the setting concerning the
analog output.
↓
Set correctly.
→ No →
↓
Yes
↓
Set correctly (refer to Chapter
).
Inform Minebea Intec about the
contents of failure and situation in
details.
Check BCD output
↓
Is wiring correct?
→ No →
↓
Yes
↓
Connect wires surely with external
equipment (refer to Chap-
ter
Except for the BCD are outputted.
→ Yes →
↓
No
↓
Match the setting concerning the
BCD output to the speciication of
external equipment connected (re-
fer to Chapter
The intended value is not output.
→ Yes →
↓
No
↓
Select the target of BCD output (re-
fer to Chapter
BCD output does not change.
→ Yes →
Set the HOLD input opened.
↓
No
↓
Inform Minebea Intec about the
contents of failure and situation in
details.