Speciications
I/O
Content
ERROR (error)
Output ON when an error occurs
For error descriptions, refer to Chapter
and
OVER
Output ON synchronizing with the OL display (overload).
Decimal point 10
1
,
decimal point 10
2
,
decimal point 10
3
,
decimal point 10
4
Output ON synchronizing with the decimal point display
setting.
Stable
Output ON when stability is detected
Gross weight
Output ON when the BCD output is gross weight.
HOLD
Input
Holding of BCD output
BCD-ENABLE
Input
The output related to BCD is compulsorily set to
high impedance.
Numbers which can be
equipped
-
Up to 2 units.
When two units are mounted, both of two units are
the same operation.
17.2.2
Switch to BCD output setting screen
Switch from the weighing screen to the BCD output setting screen by the following
procedure.
17.2.3
Setting item of BCD output
1
Operation mode
The BCD output mode is selectable from [Stream], [SYNC. WITH PRINT], [SYNC.
WITH ACCUM] or [SYNC.WITH FINISH].
[STREAM] is set as default.
2 Target of output
The target of BCD output is selectable from [LOAD DISPLAY], [Gross weight], [Net
weight], [Tare weight], [BRAND ACCUM.AMOUNT] or [BRAND ACCUM. COUNT].
[LOAD DISPLAY] is set as default.
3
BCD output logic
The logic of the BCD output is selectable from [Negative logic] or [Positive logic].
[Negative logic] is set as default.
4 POL. (polarity) Logic
The output logic of POL is selectable from [Negative logic] or [Positive logic].
[Negative logic] is set as default.
1. Select [MENU].
2. Tap [NEXT].
3. Select [OPTION].
4. Select [BCD OUTPUT].
17 Options
Weight Controller CSD-918
Minebea Intec
EN-143
Содержание CSD-918 Series
Страница 239: ......